From: Approximate solutions for MHD squeezing fluid flow by a novel method
x | OHAM | Numerical solution (RK-4) | Approximate solution RKHSM | Absolute error | Relative error | Time (s) |
---|---|---|---|---|---|---|
0.1 | 0.105312 | 0.105391 | 0.10539098947593257979 | 1.05 × 10−8 | 9.98 × 10−8 | 4.134 |
0.2 | 0.210625 | 0.210782 | 0.2107819933190829 | 6.68 × 10−9 | 3.16 × 10−8 | 5.101 |
0.3 | 0.315938 | 0.316173 | 0.3161729190893567630 | 8.09 × 10−8 | 2.55 × 10−7 | 3.010 |
0.4 | 0.421249 | 0.421563 | 0.4215629919618786430 | 8.03 × 10−9 | 1.9 × 10−8 | 3.198 |
0.5 | 0.526551 | 0.526952 | 0.5269519479728988 | 5.2 × 10−8 | 9.87 × 10−8 | 3.042 |
0.6 | 0.631824 | 0.632324 | 0.632323981769674315 | 1.82 × 10−8 | 2.88 × 10−8 | 3.074 |
0.7 | 0.736971 | 0.737586 | 0.7375860570172070642 | 5.7 × 10−8 | 7.73 × 10−8 | 3.089 |
0.8 | 0.841352 | 0.842051 | 0.84205103495023398982 | 3.49 × 10−8 | 4.15 × 10−8 | 3.073 |
0.9 | 0.94035 | 0.940861 | 0.94086101815219431313 | 1.81 × 10−8 | 1.92 × 10−8 | 3.135 |
1.0 | 1.0 | 1.0 | 1.0 | 0.0 | 0.0 | 2.902 |