Skip to main content

Table 1 Comparison of local Nusselt number \(- \theta '(0)\) in the case of Newtonian fluid (\(\beta = \gamma = b = f_{w} = 0\)) for different values of Pr

From: Heat transfer over a steady stretching surface in the presence of suction

Pr

Wang [35]

Gorla and Sidawi [36]

Khan and Pop [37]

Malik et al. [38]

HWQM

RK Gill

0.70

0.4539

0.5349

0.4539

0.45392

0.453930

0.453917

2.00

0.9114

0.9114

0.9113

0.91135

0.911345

0.911358

7.00

1.8954

1.8905

1.8954

1.89543

1.895489

1.895403

20.0

3.3539

3.3539

3.3539

3.35395

3.353905

3.353904